Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Nutrients ; 15(2)2023 Jan 12.
Article in English | MEDLINE | ID: mdl-36678261

ABSTRACT

Background & aims: Iodine is important for thyroid function during pregnancy to support fetal growth, but studies of maternal iodine status and birth outcomes are conflicting. We aimed to quantify the association between iodine status and birth outcomes, including potential threshold effects using nonlinear dose−response curves. Methods: We systematically searched Medline and Embase to 10 October 2022 for relevant cohort studies. We conducted random-effects meta-analyses of urinary iodine concentration (UIC), iodine:creatinine ratio (I:Cr), and iodide intake for associations with birth weight, birth weight centile, small for gestational age (SGA), preterm delivery, and other birth outcomes. Study quality was assessed using the Newcastle-Ottawa scale. Results: Meta-analyses were conducted on 23 cohorts with 42269 participants. Birth weight was similar between UIC ≥ 150 µg/L and <150 µg/L (difference = 30 g, 95% CI −22 to 83, p = 0.3, n = 13, I2 = 89%) with no evidence of linear trend (4 g per 50 µg/L, −3 to 10, p = 0.2, n = 12, I2 = 80%). I:Cr was similar, but with nonlinear trend suggesting I:Cr up to 200 µg/g associated with increasing birthweight (p = 0.02, n = 5). Birthweight was 2.0 centiles (0.3 to 3.7, p = 0.02, n = 4, I2 = 0%) higher with UIC ≥ 150 µg/g, but not for I:Cr. UIC ≥ 150 µg/L was associated with lower risk of SGA (RR = 0.85, 0.75 to 0.96, p = 0.01, n = 13, I2 = 0%), but not with I:Cr. Conclusions: The main risk of bias was adjustment for confounding, with variation in urine sample collection and exposure definition. There were modest-sized associations between some measures of iodine status, birth weight, birth weight centile, and SGA. In pregnancy, we recommend that future studies report standardised measures of birth weight that take account of gestational age, such as birth weight centile and SGA. Whilst associations were modest-sized, we recommend maintaining iodine sufficiency in the population, especially for women of childbearing age on restricted diets low in iodide.


Subject(s)
Iodine , Premature Birth , Female , Humans , Infant, Newborn , Pregnancy , Birth Weight/physiology , Fetal Development , Fetal Growth Retardation , Iodides , Iodine/urine , Parturition , Premature Birth/epidemiology
2.
Open Heart ; 9(2)2022 10.
Article in English | MEDLINE | ID: mdl-36192035

ABSTRACT

BACKGROUND: There is a paucity of real-world data assessing the association of operator volumes and mortality specific to primary percutaneous coronary intervention (PPCI). METHODS: Demographic, clinical and outcome data for all patients undergoing PPCI in Leeds General Infirmary, UK, between 1 January 2009 and 31 December 2011, and 1 January 2013 and 31 December 2013, were obtained prospectively. Operator volumes were analysed according to annual operator PPCI volume (low volume: 1-54 PPCI per year; intermediate volume: 55-109 PPCI per year; high volume: ≥110 PPCI per year). Cox proportional hazards regression analyses were undertaken to investigate 30-day and 12-month all-cause mortality, adjusting for confounding factors. RESULTS: During this period, 4056 patients underwent PPCI, 3703 (91.3%) of whom were followed up for a minimum of 12 months. PPCI by low-volume operators was associated with significantly higher adjusted 30-day mortality (HR 1.48 (95% CI 1.05 to 2.08); p=0.02) compared with PPCI performed by high-volume operators, with no significant difference in adjusted 12-month mortality (HR 1.26 (95% CI 0.96 to 1.65); p=0.09). Comparisons between low-volume and intermediate-volume operators, and between intermediate and high-volume operators, showed no significant differences in 30-day and 12-month mortality. CONCLUSIONS: Low operator volume is independently associated with higher probability of 30-day mortality compared with high operator volume, suggesting a volume-outcome relationship in PPCI at a threshold higher than current recommendations.


Subject(s)
Myocardial Infarction , Percutaneous Coronary Intervention , Hospital Mortality , Humans , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Retrospective Studies , Treatment Outcome
3.
Nutrients ; 13(1)2021 Jan 14.
Article in English | MEDLINE | ID: mdl-33466826

ABSTRACT

Iodine is essential for normal thyroid function, supporting healthy fetal and child development. Iodine requirements increase in pregnancy, but many women in regions without salt iodization have insufficient intakes. We explored associations between iodide intake and urinary iodine concentration (UIC), urinary iodine/creatinine ratio (I/Cr), thyroid stimulating hormone, thyroglobulin, free triiodothyronine, free thyroxine and palpable goiter in a region of mild-to-moderate iodine insufficiency. A total of 246 pregnant women aged 18-40 in Bradford, UK, joined the Health and Iodine in Babies (Hiba) study. They provided detailed information on diet and supplement use, urine and serum samples and were assessed for goiter at around 12, 26 and 36 weeks' gestation, and 6, 18 and 30 weeks postpartum. Dietary iodide intake from food and drink was estimated using six 24 h recalls. During pregnancy, median (IQR) dietary iodide intake was 101 µg/day (54, 142), with 42% from dairy and 9% from white fish. Including supplements, intake was 143 µg/day (94, 196), with 49% < UK reference nutrient intake (140 µg/day). Women with Pakistani heritage had 129 µg/day (87, 190) median total intake. Total intake during pregnancy was associated with 4% (95% CI: 1%, 7%) higher UIC, 5% (3%, 7%) higher I/Cr, 4% (2%, 6%) lower thyroglobulin and 21% (9%, 32%) lower odds of palpable goiter per 50 µg/day. This cohort consumed less iodide in pregnancy than UK and World Health Organization dietary recommendations. UIC, I/Cr and thyroglobulin were associated with intake. Higher intake was associated with fewer goiters. Because dairy was the dominant source of iodide, women following plant-based or low-dairy diets may be at particular risk of iodine insufficiency.


Subject(s)
Deficiency Diseases , Iodides/analysis , Iodine , Maternal Nutritional Physiological Phenomena/physiology , Thyroid Hormones/blood , Adolescent , Adult , Deficiency Diseases/blood , Deficiency Diseases/epidemiology , Deficiency Diseases/urine , Diet/statistics & numerical data , Dietary Supplements/statistics & numerical data , Female , Humans , Iodine/deficiency , Iodine/urine , Postpartum Period/physiology , Pregnancy/statistics & numerical data , United Kingdom , Young Adult
4.
Paediatr Perinat Epidemiol ; 35(2): 236-246, 2021 03.
Article in English | MEDLINE | ID: mdl-32870514

ABSTRACT

BACKGROUND: Maternal iodine requirements increase during pregnancy to supply thyroid hormones critical for fetal neurodevelopment. Iodine insufficiency may result in poorer cognitive or child educational outcomes but current evidence is sparse and inconsistent. OBJECTIVES: To quantify the association between maternal iodine status and child educational outcomes. METHODS: Urinary iodine concentrations (UIC) and iodine/creatinine ratios (I:Cr) were measured in 6971 mothers at 26-28 weeks' gestation participating in the Born in Bradford cohort. Maternal iodine status was examined in relation to child school achievement (early years foundation stage (EYFS), phonics, and Key Stage 1 (KS1)), other learning outcomes, social and behavioural difficulties, and sensorimotor control in 5745 children aged 4-7 years. RESULTS: Median (interquartile range) UIC was 76 µg/L (46, 120), and I:Cr was 83 µg/g (59, 121). Overall, there was no strong or consistent evidence to support associations between UIC or I:Cr and neurodevelopmental outcomes. For instance, predicted EYFS and phonics scores (primary outcomes) at the 25th vs 75th I:Cr percentiles (99% confidence intervals) were similar, with no evidence of associations: EYFS scores were 32 (99% CI 31, 33) and 33 (99% CI 32, 34), and phonics scores were 34 (99% CI 33, 35) and 35 (99% CI 34, 36), respectively. CONCLUSIONS: In the largest single study of its kind, there was little evidence of detrimental neurodevelopmental outcomes in children born to pregnant women with iodine insufficiency as defined by World Health Organization-outlined thresholds. Alternative functional biomarkers for iodine status in pregnancy and focused assessment of other health outcomes may provide additional insight.


Subject(s)
Iodine , Child , Cognition , Female , Gestational Age , Humans , Nutritional Status , Pregnancy , Pregnancy, Multiple , United Kingdom/epidemiology
5.
Int J Epidemiol ; 50(2): 620-632, 2021 05 17.
Article in English | MEDLINE | ID: mdl-33330936

ABSTRACT

BACKGROUND: Directed acyclic graphs (DAGs) are an increasingly popular approach for identifying confounding variables that require conditioning when estimating causal effects. This review examined the use of DAGs in applied health research to inform recommendations for improving their transparency and utility in future research. METHODS: Original health research articles published during 1999-2017 mentioning 'directed acyclic graphs' (or similar) or citing DAGitty were identified from Scopus, Web of Science, Medline and Embase. Data were extracted on the reporting of: estimands, DAGs and adjustment sets, alongside the characteristics of each article's largest DAG. RESULTS: A total of 234 articles were identified that reported using DAGs. A fifth (n = 48, 21%) reported their target estimand(s) and half (n = 115, 48%) reported the adjustment set(s) implied by their DAG(s). Two-thirds of the articles (n = 144, 62%) made at least one DAG available. DAGs varied in size but averaged 12 nodes [interquartile range (IQR): 9-16, range: 3-28] and 29 arcs (IQR: 19-42, range: 3-99). The median saturation (i.e. percentage of total possible arcs) was 46% (IQR: 31-67, range: 12-100). 37% (n = 53) of the DAGs included unobserved variables, 17% (n = 25) included 'super-nodes' (i.e. nodes containing more than one variable) and 34% (n = 49) were visually arranged so that the constituent arcs flowed in the same direction (e.g. top-to-bottom). CONCLUSION: There is substantial variation in the use and reporting of DAGs in applied health research. Although this partly reflects their flexibility, it also highlights some potential areas for improvement. This review hence offers several recommendations to improve the reporting and use of DAGs in future research.


Subject(s)
Research , Bias , Causality , Confounding Factors, Epidemiologic , Data Interpretation, Statistical , Humans
6.
BMC Pediatr ; 20(1): 544, 2020 12 05.
Article in English | MEDLINE | ID: mdl-33276760

ABSTRACT

BACKGROUND: Maternal iodine requirements increase during pregnancy to supply thyroid hormones essential for fetal brain development. Maternal iodine deficiency can lead to hypothyroxinemia, a reduced fetal supply of thyroid hormones which, in the first trimester, has been linked to an increased risk of autism spectrum disorder (ASD) in the child. No study to date has explored the direct link between maternal iodine deficiency and diagnosis of ASD in offspring. METHODS: Urinary iodine concentrations (UIC) and iodine/creatinine ratios (I:Cr) were measured in 6955 mothers at 26-28 weeks gestation participating in the Born in Bradford (BiB) cohort. Maternal iodine status was examined in relation to the probability of a Read (CTV3) code for autism being present in a child's primary care records through a series of logistic regression models with restricted cubic splines. RESULTS: Median (inter-quartile range) UIC was 76 µg/L (46, 120) and I:Cr was 83 µg/g (59, 121) indicating a deficient population according to WHO guidelines. Ninety two children (1·3%) in our cohort had received a diagnosis of ASD by the census date. Overall, there was no evidence to support an association between I:Cr or UIC and ASD risk in children aged 8-12 years (p = 0·3). CONCLUSIONS: There was no evidence of an increased clinical ASD risk in children born to mothers with mild-to-moderate iodine deficiency at 26 weeks gestation. Alternative functional biomarkers of exposure and a wider range of conditions may provide further insight.


Subject(s)
Autism Spectrum Disorder , Iodine , Autism Spectrum Disorder/etiology , Child , Female , Fetal Development , Gestational Age , Humans , Pregnancy , United Kingdom/epidemiology
7.
BMC Med ; 18(1): 132, 2020 06 11.
Article in English | MEDLINE | ID: mdl-32522280

ABSTRACT

BACKGROUND: Severe iodine insufficiency in pregnancy has significant consequences, but there is inadequate evidence to indicate what constitutes mild or moderate insufficiency, in terms of observed detrimental effects on pregnancy or birth outcomes. A limited number of studies have examined iodine status and birth outcomes, finding inconsistent evidence for specific outcomes. METHODS: Maternal iodine status was estimated from spot urine samples collected at 26-28 weeks' gestation from 6971 mothers in the Born in Bradford birth cohort. Associations with outcomes were examined for both urinary iodine concentration (UIC) and iodine-to-creatinine ratio (I:Cr). Outcomes assessed included customised birthweight (primary outcome), birthweight, small for gestational age (SGA), low birthweight, head circumference and APGAR score. RESULTS: There was a small positive association between I:Cr and birthweight in adjusted analyses. For a typical participant, the predicted birthweight centile at the 25th percentile of I:Cr (59 µg/g) was 2.7 percentage points lower than that at the 75th percentile of I:Cr (121 µg/g) (99% confidence interval (CI) 0.8 to 4.6), birthweight was predicted to be 41 g lower (99% CI 13 to 69) and the predicted probability of SGA was 1.9 percentage points higher (99% CI 0.0 to 3.7). There was no evidence of associations using UIC or other birth outcomes, including stillbirth, preterm birth, ultrasound growth measures or congenital anomalies. CONCLUSION: Lower maternal iodine status was associated with lower birthweight and greater probability of SGA. Whilst small, the effect size for lower iodine on birthweight is comparable to environmental tobacco smoke exposure. Iodine insufficiency is avoidable, and strategies to avoid deficiency in women of reproductive age should be considered. TRIAL REGISTRATION: ClinicalTrials.gov NCT03552341. Registered on June 11, 2018.


Subject(s)
Congenital Abnormalities/epidemiology , Fetal Growth Retardation/epidemiology , Iodine/metabolism , Mothers/statistics & numerical data , Pregnancy Outcome/epidemiology , Adult , Birth Weight , Female , Humans , Infant, Newborn , Male , Pregnancy , United Kingdom
8.
Cancer Immunol Immunother ; 69(4): 559-568, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31974724

ABSTRACT

OBJECTIVES: The neutrophil-lymphocyte ratio (NLR) is an inflammatory biomarker which is useful in cancer prognostication. We aimed to investigate the differences in baseline NLR between patients with localised and metastatic cutaneous melanoma and how this biomarker changed over time with the recurrence of disease. METHODS: This multicentre cohort study describes patients treated for Stage I-III cutaneous melanoma over 10 years. The baseline NLR was measured immediately prior to surgery and again at the time of discharge or disease recurrence. The odds ratios (OR) for sentinel node involvement are estimated using mixed-effects logistic regression. The risk of recurrence is estimated using multivariable Cox regression. RESULTS: Overall 1489 individuals were included. The mean baseline NLR was higher in patients with palpable nodal disease compared to those with microscopic nodal or localised disease (2.8 versus 2.4 and 2.3, respectively; p < 0.001). A baseline NLR ≥ 2.3 was associated with 30% higher odds of microscopic metastatic melanoma in the sentinel lymph node [adjusted OR 1.3 (95% CI 1.3, 1.3)]. Following surgery, 253 patients (18.7%) developed recurrent melanoma during surveillance although there was no statistically significant association between the baseline NLR and the risk of recurrence [adjusted HR 0.9 (0.7, 1.1)]. CONCLUSION: The NLR is associated with the volume of melanoma at presentation and may predict occult sentinel lymph metastases. Further prospective work is required to investigate how NLR may be modelled against other clinicopathological variables to predict outcomes and to understand the temporal changes in NLR following surgery for melanoma.


Subject(s)
Lymphocytes/pathology , Melanoma/blood , Neutrophils/pathology , Skin Neoplasms/blood , Aged , Aged, 80 and over , Cohort Studies , Female , Humans , Kaplan-Meier Estimate , Leukocyte Count , Lymphatic Metastasis , Male , Melanoma/pathology , Melanoma/surgery , Middle Aged , Neoplasm Staging , Skin Neoplasms/pathology , Skin Neoplasms/surgery , Melanoma, Cutaneous Malignant
9.
Open Heart ; 6(1): e000951, 2019.
Article in English | MEDLINE | ID: mdl-31328001

ABSTRACT

Background: There is a paucity of real-world outcome data comparing clopidogrel, prasugrel and ticagrelor in primary percutaneous coronary intervention (PPCI) for ST-segment elevation myocardial infarction (STEMI). We sought to assess the association of choice of oral P2Y12-receptor inhibitor with clinical outcomes following PPCI for STEMI in a large consecutive patient series. Methods: Demographic, procedural and 12-month outcome data were prospectively collected for all patients undergoing PPCI in Leeds, UK, between 01 January 2009 and 31 December 2011, and 01 January 2013 and 31 December 2013. Clinical endpoints were 30-day and 12-month all-cause mortality, recurrent MI and 30-day HORIZONS-major bleeding. Logistic regression analyses were undertaken to adjust for confounding factors. Results: Prasugrel (n=1244) was associated with lower adjusted 30-day (OR 0.53 (0.34-0.85)) and 12-month (OR 0.55 (0.38-0.78)) mortality, and 12-month MI (OR 0.63 (0.42-0.94)) compared with clopidogrel (n=1648). Importantly, prasugrel was associated with lower adjusted 30-day mortality (OR 0.51 (0.29-0.91)) compared with ticagrelor (n=811). Lower 30-day (OR 0.40 (0.17-0.94)) and 12-month (OR 0.54 (0.32-0.93)) MI were observed in ticagrelor compared with clopidogrel, an association absent in comparison with prasugrel. Adjusted bleeding were not statistically significantly different among the P2Y12-receptor inhibitors. Conclusion: In this large consecutive real-world series, prasugrel was associated with lower adjusted 30-day mortality compared with ticagrelor and clopidogrel, and lower adjusted 12-month mortality compared with clopidogrel. Both prasugrel and ticagrelor were associated with lower recurrent MI following PPCI compared with clopidogrel, with no overall increase in adjusted bleeding.

10.
J Magn Reson Imaging ; 50(3): 771-778, 2019 09.
Article in English | MEDLINE | ID: mdl-30756434

ABSTRACT

BACKGROUND: Imaging biomarkers, such as the T1 relaxation time of the myocardium using MRI, can be valuable in cardiac medicine if they are properly validated. Consensus statements recommend that for myocardial T1 , each investigator should establish a reference range. PURPOSE: To describe a statistically valid method for determining and reporting the reference range in each center, which simultaneously minimizes the twin risks of undersampling, leading to a uselessly uncertain range, and oversampling, which exposes volunteers to unnecessary scanning and wastes resources. STUDY TYPE: Cohort. POPULATION: In all, 278 normal human subjects without cardiac disease from two cardiac MR centers. FIELD STRENGTH/SEQUENCE: 1.5 T and 3 T; Modified Look-Locker Inversion recovery sequence. ASSESSMENT: The T1 relaxation time was estimated from multiple samples of tissue magnetization after inversion. A valid method for calculating a reference range was used. STATISTICAL TESTS: Shapiro-Wilk test for normality; Tukey robust approach for identification of outliers; reference range calculation with confidence intervals. RESULTS: Reference ranges for measurement of myocardial T1 were calculated, with confidence intervals, enabling comparison with clinically important differences. At 3 T: 1129 to 1301 msec at site 1 (n = 21) and 1160 to 1309 msec at site 2 (n = 59), and at 1.5 T at site 2: 933 to 1020 msec (male, n = 130) and 965 to 1054 msec (female, n = 68). The 3 T reference range from site 1 was successfully benchmarked against the 3 T reference range at site 2. DATA CONCLUSION: Myocardial T1 reference ranges can be properly characterized, enabling clinical comparison to a valid reference range with known confidence intervals, using methodology similar to that described in this report. LEVEL OF EVIDENCE: 3 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2019;50:771-778.


Subject(s)
Heart/anatomy & histology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Biomarkers , Cohort Studies , Female , Humans , Male , Middle Aged , Reference Values , Reproducibility of Results
11.
Nutrients ; 11(2)2019 Feb 20.
Article in English | MEDLINE | ID: mdl-30791590

ABSTRACT

Severe iodine deficiency in mothers is known to impair foetal development. Pregnant women in the UK may be iodine insufficient, but recent assessments of iodine status are limited. This study assessed maternal urinary iodine concentrations (UIC) and birth outcomes in three UK cities. Spot urines were collected from 541 women in London, Manchester and Leeds from 2004⁻2008 as part of the Screening for Pregnancy End points (SCOPE) study. UIC at 15 and 20 weeks' gestation was estimated using inductively coupled plasma-mass spectrometry (ICP-MS). Associations were estimated between iodine status (UIC and iodine-to-creatinine ratio) and birth weight, birth weight centile (primary outcome), small for gestational age (SGA) and spontaneous preterm birth. Median UIC was highest in Manchester (139 µg/L, 95% confidence intervals (CI): 126, 158) and London (130 µg/L, 95% CI: 114, 177) and lowest in Leeds (116 µg/L, 95% CI: 99, 135), but the proportion with UIC <50 µg/L was <20% in all three cities. No evidence of an association was observed between UIC and birth weight centile (-0.2% per 50 µg/L increase in UIC, 95% CI: -1.3, 0.8), nor with odds of spontaneous preterm birth (odds ratio = 1.00, 95% CI: 0.84, 1.20). Given the finding of iodine concentrations being insufficient according to World Health Organization (WHO) guidelines amongst pregnant women across all three cities, further studies may be needed to explore implications for maternal thyroid function and longer-term child health outcomes.


Subject(s)
Iodine/deficiency , Nutritional Status , Pregnancy Complications/epidemiology , Pregnancy Outcome/epidemiology , Prenatal Nutritional Physiological Phenomena , Adult , Birth Weight , Cities , Female , Gestational Age , Humans , Infant, Newborn , Infant, Small for Gestational Age , Iodine/urine , Nutrition Assessment , Pregnancy , Pregnancy Complications/etiology , Pregnancy Complications/urine , Premature Birth/epidemiology , Premature Birth/etiology , Prenatal Diagnosis/methods , United Kingdom/epidemiology
12.
Eur Heart J Acute Cardiovasc Care ; 8(3): 264-272, 2019 Apr.
Article in English | MEDLINE | ID: mdl-28980483

ABSTRACT

BACKGROUND: Female sex and South Asian race have been associated with poor clinical outcomes following primary percutaneous coronary intervention (PPCI) for ST-segment elevation myocardial infarction (STEMI) but remain understudied in large real-world series. We therefore investigated the association of sex and race with clinical outcomes following PPCI. METHODS: We conducted a prospective study of all patients undergoing PPCI for STEMI between January 2009 and December 2011 at a large UK cardiac centre. Clinical characteristics and outcomes were compared according to sex and race using Chi-square test, independent samples Student's t-test and Mann-Whitney U-test. Primary and secondary outcomes were 12-month major adverse cardiovascular events (MACEs) - defined as all-cause mortality, myocardial infarction and unplanned revascularization, analysed using Cox proportional hazard models adjusting for cardiovascular risk factors. RESULTS: Three thousand and forty-nine patients were included. Women ( n=826) were older than men ( n=2223) (median age 69 vs. 60 years, p <0.01). Mortality (hazard ratio 1.48 (1.15-1.90)) and MACE (hazard ratio 1.40 (1.14-1.72)) were higher in women in univariable analysis. However, there were no significant sex-differences in mortality or MACE after age-stratification alone. Multivariable analysis also showed no significant differences in outcomes between sexes. South Asians ( n=297) were younger but had a higher prevalence of most risk factors than White patients ( n=2570). Mortality and MACE did not differ significantly between South Asian and White patients in univariable or multivariable analysis. CONCLUSION: MACE and mortality was not greater in women, or in South Asian patients following PPCI after adjustment for cardiovascular risk factors including age, which was most strongly associated with both outcomes.


Subject(s)
Ethnicity , Percutaneous Coronary Intervention , Postoperative Complications/ethnology , Risk Assessment/methods , ST Elevation Myocardial Infarction/ethnology , Aged , Cause of Death/trends , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Risk Factors , ST Elevation Myocardial Infarction/surgery , Sex Distribution , Sex Factors , Survival Rate/trends , Treatment Outcome , United Kingdom/epidemiology
13.
Ann Surg Oncol ; 25(11): 3341-3349, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30066226

ABSTRACT

BACKGROUND: In the peripheral blood, the neutrophil-lymphocyte ratio (NLR) and platelet-lymphocyte ratio (PLR) change in response to malignancy. These biomarkers are associated with adverse outcomes in numerous cancers, but the evidence is limited in relation to melanoma. This study sought to investigate the association between these biomarkers and survival in Stages I-III cutaneous melanoma. METHODS: This multicenter cohort study investigated a consecutive series of patients who underwent wide excision of biopsy-proven cutaneous melanoma and sentinel lymph node biopsy during a 10-year period. The baseline NLR and PLR were calculated immediately before sentinel lymph node biopsy. Adjusted hazard ratios (HRs) for overall and melanoma-specific survival were generated. RESULTS: Overall, 1351 patients were included in the study. During surveillance, 184 of these patients died (14%), with 141 of the deaths (77%) attributable to melanoma. Worse overall survival was associated with a baseline NLR lower than 2.5 [HR 2.2; 95% confidence interval (CI) 2.0 to 2.3; p < 0.001] and a baseline PLR lower than 100 (HR 1.8; 95% CI 1.7 to 1.8; p < 0.001). Melanoma-specific survival also was worse, with a baseline NLR lower than 2.5 (HR 1.9; 95% CI 1.6 to 2.2; p < 0.001) and a baseline PLR lower than 100 (HR 1.9; 95% CI 1.7 to 2.2; p < 0.001). The 5-year survival for patients with sentinel lymph node metastases and a low NLR and PLR was approximately 50%. CONCLUSION: This study provides important new data on biomarkers in early-stage melanoma, which contrast with biomarker profiles in advanced disease. These biomarkers may represent the host inflammatory response to melanoma and therefore could help select patients for adjuvant therapy and enhanced surveillance.


Subject(s)
Biomarkers, Tumor/analysis , Blood Platelets/pathology , Lymphocytes/pathology , Melanoma/mortality , Neoplasm Recurrence, Local/mortality , Neutrophils/pathology , Skin Neoplasms/mortality , Female , Follow-Up Studies , Humans , Lymphatic Metastasis , Male , Melanoma/pathology , Melanoma/surgery , Middle Aged , Neoplasm Invasiveness , Neoplasm Recurrence, Local/pathology , Neoplasm Recurrence, Local/surgery , Prognosis , Prospective Studies , Retrospective Studies , Skin Neoplasms/pathology , Skin Neoplasms/surgery , Survival Rate
14.
Int J Biostat ; 13(2)2017 09 26.
Article in English | MEDLINE | ID: mdl-28961139

ABSTRACT

Case-control studies are used in epidemiology to try to uncover the causes of diseases, but are a retrospective study design known to suffer from non-participation and recall bias, which may explain their decreased popularity in recent years. Traditional analyses report usually only the odds ratio for given exposures and the binary disease status. Chain event graphs are a graphical representation of a statistical model derived from event trees which have been developed in artificial intelligence and statistics, and only recently introduced to the epidemiology literature. They are a modern Bayesian technique which enable prior knowledge to be incorporated into the data analysis using the agglomerative hierarchical clustering algorithm, used to form a suitable chain event graph. Additionally, they can account for missing data and be used to explore missingness mechanisms. Here we adapt the chain event graph framework to suit scenarios often encountered in case-control studies, to strengthen this study design which is time and financially efficient. We demonstrate eight adaptations to the graphs, which consist of two suitable for full case-control study analysis, four which can be used in interim analyses to explore biases, and two which aim to improve the ease and accuracy of analyses. The adaptations are illustrated with complete, reproducible, fully-interpreted examples, including the event tree and chain event graph. Chain event graphs are used here for the first time to summarise non-participation, data collection techniques, data reliability, and disease severity in case-control studies. We demonstrate how these features of a case-control study can be incorporated into the analysis to provide further insight, which can help to identify potential biases and lead to more accurate study results.


Subject(s)
Case-Control Studies , Data Interpretation, Statistical , Models, Statistical , Patient Selection , Humans
15.
Am J Epidemiol ; 186(10): 1204-1208, 2017 Nov 15.
Article in English | MEDLINE | ID: mdl-28535192

ABSTRACT

Chain event graphs (CEGs) are a graphical representation of a statistical model derived from event trees. They have previously been applied to cohort studies but not to case-control studies. In this paper, we apply the CEG framework to a Yorkshire, United Kingdom, case-control study of childhood type 1 diabetes (1993-1994) in order to examine 4 exposure variables associated with the mother, 3 of which are fully observed (her school-leaving-age, amniocenteses during pregnancy, and delivery type) and 1 with missing values (her rhesus factor), while incorporating previous type 1 diabetes knowledge. We conclude that the unknown rhesus factor values were likely to be missing not at random and were mainly rhesus-positive. The mother's school-leaving-age and rhesus factor were not associated with the diabetes status of the child, whereas having at least 1 amniocentesis procedure and, to a lesser extent, birth by cesarean delivery were associated; the combination of both procedures further increased the probability of diabetes. This application of CEGs to case-control data allows for the inclusion of missing data and prior knowledge, while investigating associations in the data. Communication of the analysis with the clinical expert is more straightforward than with traditional modeling, and this approach can be applied retrospectively or when assumptions for traditional analyses are not held.


Subject(s)
Amniocentesis/statistics & numerical data , Cesarean Section/statistics & numerical data , Diabetes Mellitus, Type 1/etiology , Maternal Age , Mothers/statistics & numerical data , Prenatal Exposure Delayed Effects , Amniocentesis/adverse effects , Bayes Theorem , Case-Control Studies , Cesarean Section/adverse effects , Child , Delivery, Obstetric/adverse effects , Delivery, Obstetric/methods , Delivery, Obstetric/statistics & numerical data , Educational Status , Female , Humans , Logistic Models , Models, Statistical , Pregnancy , Rh-Hr Blood-Group System/analysis , Risk Factors , United Kingdom
16.
J Med Imaging (Bellingham) ; 4(2): 025501, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28491907

ABSTRACT

This study aimed to determine whether a reduction in radiation dose was found for percutaneous coronary interventional (PCI) patients using a cardiac interventional x-ray system with state-of-the-art image enhancement and x-ray optimization, compared to the current generation x-ray system, and to determine the corresponding impact on clinical image quality. Patient procedure dose area product (DAP) and fluoroscopy duration of 131 PCI patient cases from each x-ray system were compared using a Wilcoxon test on median values. Significant reductions in patient dose ([Formula: see text]) were found for the new system with no significant change in fluoroscopy duration ([Formula: see text]); procedure DAP reduced by 64%, fluoroscopy DAP by 51%, and "cine" acquisition DAP by 76%. The image quality of 15 patient angiograms from each x-ray system (30 total) was scored by 75 clinical professionals on a continuous scale for the ability to determine the presence and severity of stenotic lesions; image quality scores were analyzed using a two-sample [Formula: see text]-test. Image quality was reduced by 9% ([Formula: see text]) for the new x-ray system. This demonstrates a substantial reduction in patient dose, from acquisition more than fluoroscopy imaging, with slightly reduced image quality, for the new x-ray system compared to the current generation system.

17.
Diab Vasc Dis Res ; 14(2): 122-129, 2017 03.
Article in English | MEDLINE | ID: mdl-28185533

ABSTRACT

Type 2 diabetes mellitus prevalence is growing globally, and the leading cause of mortality in these patients is cardiovascular disease. Epigenetic mechanisms such as microRNAs (miRs) and DNA methylation may contribute to complications of type 2 diabetes mellitus. We discovered an aberrant type 2 diabetes mellitus-smooth muscle cell phenotype driven by persistent up-regulation of miR-145. This study aimed to determine whether elevated expression was due to changes in methylation at the miR-145 promoter. Smooth muscle cells were cultured from saphenous veins of 22 non-diabetic and 22 type 2 diabetes mellitus donors. DNA was extracted, bisulphite treated and pyrosequencing used to interrogate methylation at 11 CpG sites within the miR-145 promoter. Inter-patient variation was high irrespective of type 2 diabetes mellitus. Differential methylation trends were apparent between non-diabetic and type 2 diabetes mellitus-smooth muscle cells at most sites but were not statistically significant. Methylation at CpGs -112 and -106 was consistently lower than all other sites explored in non-diabetic and type 2 diabetes mellitus-smooth muscle cells. Finally, miR-145 expression per se was not correlated with methylation levels observed at any site. The persistent up-regulation of miR-145 observed in type 2 diabetes mellitus-smooth muscle cells is not related to methylation at the miR-145 promoter. Crucially, miR-145 methylation is highly variable between patients, serving as a cautionary note for future studies of this region in primary human cell types.


Subject(s)
DNA Methylation , Diabetes Mellitus, Type 2/genetics , Epigenesis, Genetic , MicroRNAs/genetics , Muscle, Smooth, Vascular/metabolism , Myocytes, Smooth Muscle/metabolism , Promoter Regions, Genetic , Adult , Aged , Aged, 80 and over , Case-Control Studies , Cells, Cultured , CpG Islands , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/metabolism , Female , Genetic Predisposition to Disease , Humans , Male , MicroRNAs/metabolism , Middle Aged , Phenotype , Saphenous Vein/metabolism , Up-Regulation
18.
Br J Radiol ; 90(1071): 20160660, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28124572

ABSTRACT

OBJECTIVE: The aim of this research was to quantify the reduction in radiation dose facilitated by image processing alone for percutaneous coronary intervention (PCI) patient angiograms, without reducing the perceived image quality required to confidently make a diagnosis. METHODS: Incremental amounts of image noise were added to five PCI angiograms, simulating the angiogram as having been acquired at corresponding lower dose levels (10-89% dose reduction). 16 observers with relevant experience scored the image quality of these angiograms in 3 states-with no image processing and with 2 different modern image processing algorithms applied. These algorithms are used on state-of-the-art and previous generation cardiac interventional X-ray systems. Ordinal regression allowing for random effects and the delta method were used to quantify the dose reduction possible by the processing algorithms, for equivalent image quality scores. RESULTS: Observers rated the quality of the images processed with the state-of-the-art and previous generation image processing with a 24.9% and 15.6% dose reduction, respectively, as equivalent in quality to the unenhanced images. The dose reduction facilitated by the state-of-the-art image processing relative to previous generation processing was 10.3%. CONCLUSION: Results demonstrate that statistically significant dose reduction can be facilitated with no loss in perceived image quality using modern image enhancement; the most recent processing algorithm was more effective in preserving image quality at lower doses. Advances in knowledge: Image enhancement was shown to maintain perceived image quality in coronary angiography at a reduced level of radiation dose using computer software to produce synthetic images from real angiograms simulating a reduction in dose.


Subject(s)
Coronary Angiography/methods , Image Enhancement/methods , Radiation Dosage , Radiography/methods , Humans , Radiographic Image Interpretation, Computer-Assisted/methods
19.
Br J Radiol ; 89(1067): 20160269, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27610932

ABSTRACT

OBJECTIVES: This study aimed to determine the impact on radiation dose and image quality of a new cardiac interventional X-ray system for trans-catheter aortic valve implantation (TAVI) patients compared to the previously-used cardiac X-ray system. METHODS: Patient dose and image data were retrospectively collected from a Philips AlluraClarity (new) and Siemens Axion Artis (reference) X-ray system. Patient dose area product (DAP) and fluoroscopy duration of 41 patient cases from each X-ray system were compared using a Wilcoxon test. Ten patient aortograms from each X-ray system were scored by 32 observers on a continuous scale to assess the clinical image quality at the given phase of the TAVI procedure. Scores were dichotomised by acceptability and analysed using a Chi-squared test. RESULTS: Significant reductions in patient dose (p << 0.001) were found for the new system with no significant change in fluoroscopy duration (p = 0.052); procedure DAP reduced by 55%, fluoroscopy DAP by 48% and "cine" acquisition DAP by 61%. There was no significant difference between image quality scores of the two X-ray systems (p = 0.06). CONCLUSIONS: The new cardiac X-ray system demonstrated a very significant reduction in patient dose with no loss of clinical image quality. Advances in Knowledge: The huge growth of TAVI may impact on the radiation exposure of cardiac patients and particularly on operators including anaesthetists; cumulative exposure of interventional cardiologists performing high volume TAVI over 30-40 years may be harmful. The Phillips Clarity upgrade including improved image enhancement and optimised X-ray settings significantly reduced radiation without reducing clinically acceptable image quality.


Subject(s)
Radiography, Interventional/instrumentation , Radiography, Thoracic/instrumentation , Transcatheter Aortic Valve Replacement , Fluoroscopy , Humans , Radiation Dosage , Retrospective Studies , Risk Factors , Time Factors
20.
Br J Radiol ; 89(1063): 20160094, 2016 Jul.
Article in English | MEDLINE | ID: mdl-26975497

ABSTRACT

The assessment of image quality in medical imaging often requires observers to rate images for some metric or detectability task. These subjective results are used in optimization, radiation dose reduction or system comparison studies and may be compared to objective measures from a computer vision algorithm performing the same task. One popular scoring approach is to use a Likert scale, then assign consecutive numbers to the categories. The mean of these response values is then taken and used for comparison with the objective or second subjective response. Agreement is often assessed using correlation coefficients. We highlight a number of weaknesses in this common approach, including inappropriate analyses of ordinal data and the inability to properly account for correlations caused by repeated images or observers. We suggest alternative data collection and analysis techniques such as amendments to the scale and multilevel proportional odds models. We detail the suitability of each approach depending upon the data structure and demonstrate each method using a medical imaging example. Whilst others have raised some of these issues, we evaluated the entire study from data collection to analysis, suggested sources for software and further reading, and provided a checklist plus flowchart for use with any ordinal data. We hope that raised awareness of the limitations of the current approaches will encourage greater method consideration and the utilization of a more appropriate analysis. More accurate comparisons between measures in medical imaging will lead to a more robust contribution to the imaging literature and ultimately improved patient care.


Subject(s)
Diagnostic Imaging/standards , Quality Assurance, Health Care/methods , Algorithms , Humans , Models, Theoretical
SELECTION OF CITATIONS
SEARCH DETAIL
...